DLE30-75-2 Air Driven Gas Booster

Maximator Air Driven Gas Boosters for boosting Nitrogen, Oxygen, Helium, Hydrogen etc

DLE15 75 2 DLE5 30

This email address is being protected from spambots. You need JavaScript enabled to view it.RFQ Icon

Technical Data

Style: DOUBLE ACTING TWO STAGE DOUBLE AIR HEAD Catalog Number: DLE30-75-2

PRESSURE
RATIO

COMPRESSION
RATIO

SUPPLY
PRESSURE(PSI)
OUTLET
PRESSURE
(PSI)MAX

STALL
PRESSURE

CONNECTIONS

MAX FREQ. CYCLES MIN.

DISPL PER CYCLE (IN3)

MAX TEMP. F

WEIGHT (LBS)
MIN.*
MIN.**
MAX
INLET
OUTPUT
150:1 50:1 220 450 24.0xPa 21,750 150Pa+2.5Ps 9/16"-18 9/16"-18 110 3.6 210 53
NOTE:
* = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 psi maximum, 15 psi minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.
Adapter (MT30-21NFBHM4) is available to convert the 9/16"-18 connection to 1/4" FNPT. Order separately.


GAS BOOSTER SAMPLE FLOW RATES (SCFM)

CATALOG
NUMBER
Pa=90 PSI
Ps
Po
F
DLE30-75-2
500
1,000
2.36
DLE30-75-2
500
10,000
1.55
DLE30-75-2
1,500
2,000
6.98
DLE30-75-2
1,500
15,000
2.58
NOTE:
Maximum air drive pressure is 145 psi.
Minimum air drive pressure is 15 psi.
Pa = Drive air pressure (psi)
Ps = Gas supply pressure (psi)
Po = Gas outlet pressure (psi)
F = Gas flow (SCFM)
Drive air flow requirements are up to 70 SCFM for single air head boosters and up to 140 SCFM for double air head boosters.
Air drive flows as low as 30 SCFM will work but outlet gas flows will be reduced correspondingly.
Drive air should be filtered to between 5µ and 40µ and have a dew point between 0°F and 50°F.
Consult factory for conditions outside these parameters.
Inlet gas supply to the booster should be filtered to a maximum of 15µ.

 

  • Pressures to 30,000 for most gases and 5,000 for oxygen
  • Easy to install and operate
  • Compact, lightweight design
  • Single or double acting and two stage models
  • Double air head available in single and two stage boosters
  • No electrical power required
  • Requires no lubrication
  • Boosters are contaminant free
  • Units can be operated in series or parallel
  • Variety of pressure and compression ratios available
  • High pressure gas testing or process qualification
  • Charging of accumulators
  • Boosting gas pressures from nitrogen or Oxygen bottles and generators
  • Nitrogen injection for molding machines
  • Leak detection systems
  • pressure autoclaving
  • Typical Gases - air, nitrogen, helium, oxygen, carbon dioxide, nitrous oxide, neon, argon, hydrogen, carbon monoxide, methane, ethylene and natural gas

All gas boosters are available with an optional air control unit (-ACP). This package is shown below and consists of an air filter, regulator with gauge, shutoff valve and necessary fittings and hose for plumbing unregulated pilot port

HPT offers a wide variety of other accessories to assist the installation of your Maximator gas booster.

  • Gas receivers
  • Pressure gauges
  • Air pilot pressure switches
  • Filters
  • High pressure valves, fittings and tubing
  • Miscellaneous plumbing components
* = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 maximum, 15 minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.

Air Control Unit (-ACP)
Air pilot pressure switches
Filters
Gas receivers
High pressure valves, fittings and tubing
Miscellaneous plumbing components
Pressure gauges

 