Maximator Air Driven Gas Boosters suitable for boosting Most inert Gases such as : Nitrogen, Oxygen, CO2, Helium, Argon, Xenon and many more

Technical Data

PRESSURE RATIO   2:1
COMPRESSION RATIO 10:1
SUPPLY PRESSURE(PSI) MIN.* 0
MIN.** 60
MAX 580
MAX OUTLET PRESSURE(PSI)   580
STALL PRESSURE 2Pa+Ps
CONNECTIONS INLET 1
OUTPUT 3/4
MAX CYCLE RATE   90
DISPL PER CYCLE (IN3) 112.5
MAX TEMP. F 140
WEIGHT (LBS) 45
NOTE:
* = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 psi maximum, 15 psi minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.

 

  • Pressures to 30,000 for most gases and 5,000 for oxygen
  • Easy to install and operate
  • Compact, lightweight design
  • Single or double acting and two stage models
  • Double air head available in single and two stage boosters
  • No electrical power required
  • Requires no lubrication
  • Boosters are contaminant free
  • Units can be operated in series or parallel
  • Variety of pressure and compression ratios available
  • High pressure gas testing or process qualification
  • Charging of accumulators
  • Boosting gas pressures from nitrogen or Oxygen bottles and generators
  • Nitrogen injection for molding machines
  • Leak detection systems
  • pressure autoclaving
  • Typical Gases - air, nitrogen, helium, oxygen, carbon dioxide, nitrous oxide, neon, argon, hydrogen, carbon monoxide, methane, ethylene and natural gas

All gas boosters are available with an optional air control unit (-ACP). This package is shown below and consists of an air filter, regulator with gauge, shutoff valve and necessary fittings and hose for plumbing unregulated pilot port

HPT offers a wide variety of other accessories to assist the installation of your Maximator gas booster.

  • Gas receivers
  • Pressure gauges
  • Air pilot pressure switches
  • Filters
  • High pressure valves, fittings and tubing
  • Miscellaneous plumbing components
* = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 maximum, 15 minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.

Air Control Unit (-ACP)
Air pilot pressure switches
Filters
Gas receivers
High pressure valves, fittings and tubing
Miscellaneous plumbing components
Pressure gauges

 

DLE2 Flow Chart

DLE2 Pressure 4 Bar

DLE2 Pressure 4 Bar
+

DLE2 Pressure 6 Bar

DLE2 Pressure 6 Bar
+

DLE2 Pressure 8 Bar

DLE2 Pressure 8 Bar
+

 

GAS BOOSTER SAMPLE FLOW RATES (SCFM)

CATALOG
NUMBER
Pa=90 PSI
Ps
Po
F
DLE2
60
120
12.10
DLE2
60
200
5.00
DLE2
90
150
17.00
DLE2
90
250
3.85
NOTE:
Maximum air drive pressure is 145 psi.
Minimum air drive pressure is 15 psi.
Pa = Drive air pressure (psi)
Ps = Gas supply pressure (psi)
Po = Gas outlet pressure (psi)
F = Gas flow (SCFM)
Drive air pressure operating range is 15-145 psi. Flows above are with 90 psi air drive, unless noted.
Drive air flow requirements are up to 70 SCFM per air head, and up to 280 SCFM (total) for 8DLE models. Reduced air drive flow will produce lower gas flow.
Drive air should be filtered to between 5μ and 40μ and have a dew point between 0°F and 50°F.
Consult HPT for performance values on specific application parameters.