Triple Air Head - Two Stage - Double Acting Gas Booster (DLE30-75-3-36)

Maximator DLE30-75-3-36 Gas Booster

Capable Of Pressures As High As 36,000 PSI

This email address is being protected from spambots. You need JavaScript enabled to view it.RFQ Icon
 

Pressure Ratio

Compression Ratio

Min. Supply Pressure (Basic Operation)
Min. Supply Pressure (Maximum Outlet)MAX

Max. Supply Pressure

Max. Outlet Pressure

Stall Pressure

Inlet Gas Connection

Outlet Connection

Max. Freq
Displacement. per Cycle
Max. Temperature
Weight
225:1 50:1 440 psi 7,500 30.0 x Pa psi 36,000 psi 225Pa + 2.5Ps 1/4" NPT 9/16"-18 UNF 100 Cycles/min 3.6 cubic inches in³ 212 F ºF 80 lb

 

  • Pressures to 36,000 psi for most gases and 5,000 psi for oxygen
  • Easy to install and operate
  • Compact, lightweight design
  • Single or double acting and two stage models
  • Double air head available in single and two stage boosters
  • No electrical power required
  • Requires no lubrication
  • Boosters are contaminant free
  • Units can be operated in series or parallel
  • Variety of pressure and compression ratios available
  • High pressure gas testing or process qualification
  • Charging of accumulators
  • Boosting gas pressures from nitrogen or Oxygen bottles and generators
  • Nitrogen injection for molding machines
  • Leak detection systems
  • Pressure autoclaving
  • Typical Gases - air, nitrogen, helium, oxygen, carbon dioxide, nitrous oxide, neon, argon, hydrogen, carbon monoxide, methane, ethylene and natural gas

Gas boosters are available with an optional air control unit (-ACP). This package is shown below and consists of an air filter, regulator with gauge, shutoff valve and necessary fittings and hose for plumbing unregulated pilot port.

HPT offers a wide variety of other accessories to assist the installation of your Maximator gas booster.

  • Gas receivers
  • Pressure gauges
  • Air pilot pressure switches
  • Filters
  • High pressure valves, fittings and tubing
  • Miscellaneous plumbing components
* = Minimum required for basic operation
** = Minimum required to achieve maximum outlet pressures
Pa = Drive air pressure, 145 psi maximum, 15 psi minimum
Ps = Gas supply (suction) pressure
The 9/16-18 is a 1/4" O.D. tubing, high pressure coned and threaded connection.
Stall pressure must not be allowed to exceed outlet pressure rating.
Compression ratio is the minimum required ratio of outlet pressure/supply pressure.
  • Air Control Unit (-ACP)
  • Air pilot pressure switches
  • Filters
  • Gas receivers
  • High pressure valves, fittings and tubing
  • Miscellaneous plumbing components
  • Pressure gauges

 

DLE30-75-3-36 Flow Chart

DLE30-75-3-36 Gas Booster Flow Chart