Gas Booster Air Amplifier Liquid Pump Maximator Maxpro

Pipe Connection Valves

Pipe Connection Valves

MAXIMATOR Pipe Connection Valve
Pressures to 15,200 psi

MAXIMATOR pipe valves with metal to metal seats have a high level of safety and reliability under adverse operating conditions. These valves may be used both with gases and liquids.

Traceability is ensured through extensively documented data (batch number, maximum pressure, material number, type designation). All pipe valves come with female national pipe threads (FNPT).

Ordering Information

Typical catalog number: 15V4PO71

15V 4P 07 1
Valve
Series
Pipe Size Stem Type Body Pattern
15V 4P – 1/4" NPT
6P – 3/8" NPT
07 – VEE stem
08 – REGULATING        stem
       (tapered tip for
       regulating and
       shutoff)
1 – two-way straight

 

Temperature Ranges

Standard valves are supplied with Teflon/Carbon packing and may be operated to 450°F. Consult HPT for higher temperature packing ratings.

 

Repair Kits

Consult your HPT representative for repair kits and valve bodies. Refer to the Tools and Installation section for proper maintenance procedures.

O.D. Size (in.) Connection
Type
Orifice Size (in.) Rated Cv* Pressure/Temp. Rating
(psi @ R.T.)**
1/4 1/4 FNPT 0.219 0.75 15,200
3/8 3/8 FNPT 0.312 1.30 15,200
 
* Cv values shown are for 2-way straight pattern vee stem valves. .
** See page 2 in the Technical Section for Pressure/Temperature Rating Chart.
 
Catalog
Number
Stem
Type
Pipe
Size
Orifice
(in.)
Dimensions (in.) Valve
Panel
Hole
Block
Thick-
ness
A B C D E F H I J
15V4P071 Vee 1/4 0.219 4.61 2.01 1.62 0.22 0.37 1.24 2.95 1.19 2.01 0.75 0.79
15V4P081 Reg
15V6P071 Vee 3/8 0.312 6.35 2.88 2.38 0.22 0.37 1.38 3.94 1.75 2.50 1.00 1.02
15V6P081 Reg
All general terms and conditions of sale, including limitations of
our liability, apply to all products and services sold.
G - Panel mounting screw thread size 10-24 UNC.
All dimensions are for reference only and are subject to change.