Gas Booster Air Amplifier Liquid Pump Maximator Maxpro

Air Amplifiers - Technical Information

Air Amplifiers - Technical Information

STYLE

CATALOG
NUMBER

PRESSURE
RATIO
COMPRESSION
RATIO
SUPPLY
PRESSURE (PSI)
MAX.
RATED
PRESSURE
PSI)
STALL
PRESSURE
CONNECTIONS MAX.
TEMP.
F
WEIGHT
(LBS.)
MIN. MAX. INLET OUTLET

SINGLE ACTING

DLA5-1

5:1

15:1

30

725

725

5Pa

3/8

3/8

140

35

DLA15-1

15:1

20:1

100

2175

2175

15Pa

1/4

1/4

210

35

DLA30-1

30:1

20:1

220

4350

4350

30Pa

9/16 – 18

9/16 – 18

210

35

DOUBLE ACTING

BPLV2

2:1

-

15

125

250

2Pa

1/4

1/4

160

4

MPLV2

2:1

-

15

150

300

Pa + Ps

1/4

1/4

180

12

SPLV2

2:1

-

15

150

300

Pa + Ps

3/8

3/8

180

18

GPLV2

2:1

-

25

150

300

Pa + Ps

3/8

3/8

180

45

DLA5

5:1

15:1

30

1450

1450

5Pa + Ps

3/8

3/8

140

48

DLA15

15:1

20:1

100

4350

4350

15Pa + Ps

1/4

1/4

210

48

NOTE: Pa = Air Drive Pressure (PSI) Ps = Supply Pressure (PSI)
Maximum air drive pressure 145 psi
Maximum operating and stall pressures must not be allowed to exceed output pressure rating.
The 9/16–18 is a 1/4" O.D. tubing, high pressure coned and threaded connection, all other connections are FNPT.
Air drive inlet connection on BPLV2 and MPLV2 is 1/4" FNPT.
Air drive inlet connection on all other air amplifiers is 1/2" FNPT.
There is a 1/8" FNPT pilot port on all amplifiers, except BPLV2 and MPLV2, that must be plumbed from air source.